  • 3(1761533154962).jpg

F61IMU Fiber Optic Inertial Unit

Keyword:

Introduction

Accessories

Recommendations

I Introduction

The Inertial Measurement Unit (IMU) features advantages such as compact size, light weight, low power consumption, and high precision. It can be used to design pure strapdown, single-axis, and dual-axis modulated inertial navigation systems, meeting the demand for small-size, high-precision inertial navigation equipment in new unmanned platforms, underwater/torpedo weaponry, as well as land-based and airborne weapon platforms. It possesses the capability for dynamic measurement of carrier angular and linear motion information.

II.Technical Parameters

Item

Indicator

Description

Parameter

Remark

Gyro

Zero Bias

Bias Stability (100s)

0.03°/h

 

Zero Bias Stability at Variable Temperature (100s)

0.1°/h

Temperature Variation Rate 1℃/min(-40℃~60℃)

Scaling Factor

Scale Factor Nonlinearity

≤20ppm

 

Other Indicators

Random Walk Coefficient

0.005°/½h

 

Input Range

400°/s

 

Accelerometer

Deviation

Zero Bias Repeatability

50μg

 

Zero Bias

Bias Temperature Sensitivity

50μg/℃

 

Scaling Factor

Scale Factor Repeatability

50ppm

 

Scale Factor Temperature Sensitivity

50ppm/℃

 

Range Indicators

Input Range

±20g

 

Characteristics

Environmental Performance

Operating Temperature

-40℃60℃

 

Storage Temperature

-45℃70℃

 

General Requirements

Power Supply

1836VDC

 

Stable Power Consumption

≤16W

Startup Power Consumption ≤20W

Mounting Hole Diameter

4-Φ4.5mm

 

Dimensions(mm)

110×110×100

 

Weight

 

 

III Electrical Interface Definition  (J30JM-25ZKP43)

Pinout

Signal

Type

Description

Remark

1,14

+24V

Input

Power Input

+24V

2,15

GND

Input

10

RS422_TX1+

Output

RS422 Serial Port 1

Debugging Interface

9

RS422_TX1-

Output

21

RS422_RX1+

Input

22

RS422_RX1-

Input

7

RS422_TX2+

Output

RS422 Serial Port 2

IMU Raw Data

6

RS422_TX2-

Output

20

RS422_RX2+

Input

8

RS422_RX2-

Input

12

RS422_TX2+

Output

RS422 Serial Port 3

IMU Synchronization Signal

11

RS422_TX2-

Output

24

RS422_RX2+

Input

25

RS422_RX2-

Input

 

IV Structure Diagram